1200 series hplc system (Agilent technologies)
98
Structured Review
Agilent technologies
1200 series hplc system
1200 Series Hplc System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 98/100, based on 2085 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hplc+1200+series/PLRP-S/pm39838819__bc4c00457_si_001-14-13-12
Average 98 stars, based on 2085 article reviews
1200 Series Hplc System, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 98/100, based on 2085 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/hplc+1200+series/PLRP-S/pm39838819__bc4c00457_si_001-14-13-12
Average 98 stars, based on 2085 article reviews
1200 series hplc system - by Bioz Stars,
2026-09
98/100 stars
Images
Related Articles
High Performance Liquid Chromatography:Article Title: Ammonium based ionic liquids useful for lignocellulosic processing Article Snippet: .. The filtrate was neutralized with CaCO3 and monomeric sugars were determined from the filtrate by Article Title: Does the Addition of Low-Dose Antibiotics Compromise the Mechanical Properties of Polymethylmethacrylate (PMMA)? Article Snippet: .. Concerning the LC-MS/MS conditions, chromatographic separation was performed on a Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 9 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Mightysil Aqua RP18, 250 × 4.6 mm, 5 μm Mobile Phase 98.5% (0.25% NaOAc; pH 5.5)/1.5% MeCN Flow Rate 1.0 mL/min Column Temperature 40° C. Detection Wavelength 275 nm Injection Volume 10 μL Run Time 10 min Retention Time Substrate: 6.1 min; Phenylephrine: 7.5 min. .. TABLE 9 Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 10 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Regis CBH 4.0 × 100 mm (5 μm) Mobile Phase 10% MeOH + 90% (8 mM NH4OAc + 13 μM EDTA; pH 5.5) Flow Rate 0.8 mL/min Column Temperature Ambient Detection Wavelength 275 nm Injection Volume 10 μL Run Time 5 min Retention Time R (L): 2.6 min; S(D): 3.2 min Item Analytical Parameter LOD 0.11 mg/L, S/N > 3 LOQ 0.32 mg/L, S/N > 10 A typical chromatogram from this method showed a peak at about 2.6 min and a slightly shorter broader peak at about 3.3 min. .. TABLE 10 Article Title: In Situ Eutectic Formation in a Polymeric Matrix via Hot-Melt Reactive Extrusion and the Use of Partial Least Squares Regression Modeling for Reaction Yield Determination Article Snippet: .. The analysis was carried out using an Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 7 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Mightysil Aqua RP18, 250 × 4.6 mm, 5 μm Mobile Phase 93% (0.25% NaOAc; pH 5.0)/7% MeCN Flow Rate 1.20 mL/min Column Temperature 40° C. Wavelength 275 nm Injection Volume 10 μL Run time: 6 min Retention time Product (3.3 min); Substrate (3.8 min) Item Analytical Parameter Linearity R = 1.0 (substrate); Linear Range = 0-817 mg/L R = 0.99995 (Product); Linear Range = 69.5-400 mg/L LOD 0.51 mg/L (Product); 0.17 mg/L (Substrate) LOQ 1.54 mg/L (Product); 0.43 mg/L (Substrate) An exemplary chromatogram obtained by this method under isocratic conditions showed a phenylephrine peak at 3.224 min and a slightly broader substrate peak at 3.701 min which is about two-thirds height of the phenylephrine peak. .. TABLE 7 Article Title: Evaluation of Gentamicin Release of PMMA Cements Using Different Methods: HPLC, Elution and Inhibition Zone Testing Article Snippet: .. LC-MS/MS chromatographic separation was performed on a Refractive Index:Article Title: Ammonium based ionic liquids useful for lignocellulosic processing Article Snippet: .. The filtrate was neutralized with CaCO3 and monomeric sugars were determined from the filtrate by Injection:Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 9 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Mightysil Aqua RP18, 250 × 4.6 mm, 5 μm Mobile Phase 98.5% (0.25% NaOAc; pH 5.5)/1.5% MeCN Flow Rate 1.0 mL/min Column Temperature 40° C. Detection Wavelength 275 nm Injection Volume 10 μL Run Time 10 min Retention Time Substrate: 6.1 min; Phenylephrine: 7.5 min. .. TABLE 9 Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 10 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Regis CBH 4.0 × 100 mm (5 μm) Mobile Phase 10% MeOH + 90% (8 mM NH4OAc + 13 μM EDTA; pH 5.5) Flow Rate 0.8 mL/min Column Temperature Ambient Detection Wavelength 275 nm Injection Volume 10 μL Run Time 5 min Retention Time R (L): 2.6 min; S(D): 3.2 min Item Analytical Parameter LOD 0.11 mg/L, S/N > 3 LOQ 0.32 mg/L, S/N > 10 A typical chromatogram from this method showed a peak at about 2.6 min and a slightly shorter broader peak at about 3.3 min. .. TABLE 10 Article Title: Ketoreductase polypeptides for the preparation of phenylephrine Article Snippet: TABLE 7 Chromatographic Conditions Instrument Agilent HPLC 1200 series Column Mightysil Aqua RP18, 250 × 4.6 mm, 5 μm Mobile Phase 93% (0.25% NaOAc; pH 5.0)/7% MeCN Flow Rate 1.20 mL/min Column Temperature 40° C. Wavelength 275 nm Injection Volume 10 μL Run time: 6 min Retention time Product (3.3 min); Substrate (3.8 min) Item Analytical Parameter Linearity R = 1.0 (substrate); Linear Range = 0-817 mg/L R = 0.99995 (Product); Linear Range = 69.5-400 mg/L LOD 0.51 mg/L (Product); 0.17 mg/L (Substrate) LOQ 1.54 mg/L (Product); 0.43 mg/L (Substrate) An exemplary chromatogram obtained by this method under isocratic conditions showed a phenylephrine peak at 3.224 min and a slightly broader substrate peak at 3.701 min which is about two-thirds height of the phenylephrine peak. .. TABLE 7 other:Article Title: Lubricant-Coated Organ-on-a-Chip for Enhanced Precision in Preclinical Drug Testing. Article Snippet: HPLC: The medium samples were mixed with acetonitrile and LCMS grade, in a 1:1 ratio and then centrifuged at 4 °C at 15 000 rpm for 10 min. After |